1.
Spine (Phila Pa 1976) ; 47(10): 720-729, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35019880

RESUMO

STUDY DESIGN: Experimental study. OBJECTIVE: In this study, the ambient temperature of a radiofrequency (RF) electrode tip was compared and analyzed in terms of products, mode, flow quantity, and flow rate. SUMMARY OF BACKGROUND DATA: Endoscopic spine surgery is a widely used operation for degenerative lumbar stenosis and herniated lumbar disc. To perform endoscopic spine surgery, dedicated instruments like a RF generator and electrode are essential. METHODS: An evaluation system capable of measuring temperature under equal conditions at a certain distance from the electrode tip was manufactured. The distance between the electrode tip and the temperature sensor was set to 1, 5, and 10 mm. The flow quantities of 0, 50, 100, and 150 mL/min and the flow rates of 0, 0.20, 0.53, and 0.80 m/s were compared and statistically analyzed. RESULTS: The temperatures measured in the experiments conducted on the four combinations of RF device showed similar values, and showed differences according to the characteristics of each mode of the RF. As the distance between the electrode tip and the temperature sensor increased, the temperature decreased, and as flow quantity or flow rate increased, the temperature decreased. The maximum temperatures differed significantly according to flow quantity, between flow quantities of 0 and 100 mL/min (P  = 0.03) and between 0 and 150 mL/min (P ≤ 0.01). The maximum temperatures also differed significantly between the flow rate of 0 m/s, and the flow rates of 0.20, 0.53, and 0.80 m/s, with P ≤ 0.01 in all three comparisons. CONCLUSION: This is the first study in which we made a customized RF temperature evaluation system and verified the temperature changes in various environments. When irrigation was performed, we could confirm that the maximum temperature was less than 60°C. Irrigation is considered essential in endoscopic spine surgery. LEVEL OF EVIDENCE: 3.


Assuntos
Ablação por Cateter , Temperatura Corporal , Eletrodos , Humanos , Modelos Teóricos , Temperatura
2.
Biomed Res Int ; 2021: 3454475, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34527735

RESUMO

We analyzed tunnel length, graft bending angle, and stress of the graft according to tunnel entry position and aspect ratio (ASR: ratio of anteroposterior depth to mediolateral width) of the articular surface for the distal femur during single-bundle outside-in anterior cruciate ligament reconstruction (ACLR) surgery. We performed multiflexible body dynamic analyses with four ASR (98, 105, 111, and 117%) knee models. The various ASRs were associated with approximately 1 mm changes in tunnel length. The graft bending angle increased when the entry point was far from the lateral epicondyle and was larger when the ASR was smaller. The graft was at maximum stress, 117% ASR, when the tunnel entry point was near the lateral epicondyle. The maximum stress value at a 5 mm distance from the lateral epicondyle was 3.5 times higher than the 15 mm entry position, and the cases set to 111% and 105% ASR showed 1.9 times higher stress values when at a 5 mm distance compared with a 15 mm distance. In the case set at 98% ASR, the low-stress value showed a without-distance difference from the lateral epicondyle. Our results suggest that there is no relationship between the ASR and femoral tunnel length. A smaller ASR causes a higher graft bending angle, and a larger ASR causes greater stress in the graft.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Bases de Dados Factuais , Fêmur/cirurgia , Humanos , Imageamento Tridimensional/métodos , Joelho/cirurgia , Tomografia Computadorizada por Raios X/métodos
3.
PLoS One ; 15(11): e0235239, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33166292

RESUMO

Although rotator cuff disease is a common cause of shoulder pain, there is still no treatment method that could halt or reveres its development and progression. The purpose of this study was to investigate the efficacy of umbilical cord-derived mesenchymal stem cells (UC MSCs) on the regeneration of a full-thickness rotator cuff defect (FTD) in a rat model. We injected either UC MSCs or saline to the FTD and investigated macroscopic, histological and biomechanical results and cell trafficking. Treatment with UC MSCs improved macroscopic appearance in terms of tendon thickness at two weeks, and inflammation, defect size, swelling/redness and connection surrounding tissue and slidability at four weeks compared to the saline group. Histologically, UC MSCs induced the tendon matrix formation recovering collagen organization, nuclear aspect ratio and orientation angle of fibroblast as well as suppressing cartilage-related glycosaminoglycan compared to saline group at four weeks. The UC MSCs group also improved ultimate failure load by 25.0% and 19.0% and ultimate stress by 27.3% and 26.8% at two and four weeks compared to saline group. UC MSCs labeled with PKH26 exhibited 5.3% survival at four weeks compared to three hours after injection. This study demonstrated that UC MSCs regenerated the FTD with tendon tissue similar properties to the normal tendon in terms of macroscopic, histological and biomechanical characteristics in a rat model.


Assuntos
Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais/citologia , Regeneração , Lesões do Manguito Rotador/terapia , Traumatismos dos Tendões/terapia , Animais , Fenômenos Biomecânicos , Masculino , Ratos , Ratos Sprague-Dawley , Lesões do Manguito Rotador/patologia , Traumatismos dos Tendões/patologia